3.0 Energy Efficiency

Table 3.1 shows a number of different external wall configurations and identifies which satisfy the BCA requirement for Climate Zones 1 to 8. Table 3.2 lists the component R-Values used as a basis for Table 3.1. For more information on Hebel and energy efficiency refer to Section 3 and Appendix C and D of the Hebel Technical Manual.

Table 3.1:  BCA Energy Efficiency Compliance

Wall Configuration Satisfies BCA Requirements
Climate Zone: 1* 2* 3* 4 5 6 7 8
Class 1 & Class 10a Minimum R-Value: 1.4 1.4 1.4 2.2 1.9 2.2 2.4 3.3
1. 250mm Block Only Y Y Y N Y N N N
2. 250mm Block + 25mm Cavity Y Y Y Y Y Y N N
3. 250mm Block + 25mm Cavity + Sarking Y Y Y Y Y Y Y N
4. 250mm Block + 25mm Cavity + 75mm
PowerPanel
Y Y Y Y Y Y Y N
5. 250mm Block + 40mm Cavity + R1.0
Insulation
Y Y Y Y Y Y Y N
6. 250mm Block + 25mm Cavity + Double
Sided RFL + 25mm Cavity
Y Y Y Y Y Y Y Y
7. 250mm Block + 90mm Cavity + R2.0
Insulation
Y Y Y Y Y Y Y Y

 Table 3.2:  Wall Element R-Value

System Number Construction Overall Thickness R-Value Rw Rw+ Ctr
401 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
10mm Gyprock
268 mm 2.1 48 43
402 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
28mm furring channels @600mm centres
10mm Gyprock
296mm 2.3 51 43
403 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
28mm furring channels @600mm centres
Non reflective (normal sarking)
10mm Gyprock
296mm 2.3 51 43
404 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
28mm furring channels @600mm centres
Reflective foil
10mm Gyprock
296mm 2.6 51 43
405 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
28mm furring channels @600mm centres with 50mm 11kg – Bradford Glasswool
Non reflective (sarking)
10mm Gyprock
296mm 3.1 53 44
406 8mm Render in Texture Coat and Paint
250mm Hebel PowerBlock
8mm Render in Texture Coat and Paint
216mm 2.1 48 43